7 inch live mask face recognition temperature measurement terminal
Key Features
- Use Hisilicon chip, mini version of Linux, high stability;
- Low power consumption (down to 4W);
- Support for multiple types of shells, custom appearance
- High-precision face recognition algorithm;
- Embedded algorithm, millisecond comparison;
- Accurate monocular live detection, safe and efficient;
- The accuracy rate of N library is less than 50,000, reaching 99.8%;
- Multi-scene image exposure and correction algorithm;
- Support temperature measurement, display, high temperature warning
- Support temperature interface protocol;
- Support mask reminder.
Suitable for parks, communities, communities, campuses, etc.
Technical Parameters
Technical Parameters | |
Operating system | Embedded Linux |
RAM | DDR3 8GB |
Storage | Built-in 8GB as standard, 128GB can be expanded by TF card |
Dispaly | 7 "HD IPS display |
Monocular camera | 200W pixels, 120-degree wide-angle lens, support wide dynamic, white light night vision |
Door opening method | Support face recognition |
Opening hours | <0.3 seconds (30,000 bases) |
Face recognition rate | 99.8% |
Minimum pixel | Face recognition supports minimum face pupil distance of 20 pixels |
Face library capacity | Support up to 50,000 |
Black/White list function | Support |
General parameters | |
Network | 1 RJ45 100M Ethernet port |
Communication mode | Support TCP / IP wired communication |
Power supply | DC 9~18V/3A,4W |
Work temperature | -35℃~75℃ |
Installation characteristics | Installation and use of supporting gates / speed doors |
Custom services | Appearance can be customized, customization is chargeable |
Temperature measurement module parameters | |
Temperature measurement distance | <1m |
Best distance | 0.5-0.8m |
Temperature measurement accuracy | ±0.3 |
Temperature measurement range | -40-85℃ |
Effective emissivity | 0.97±0.02 |
Wavelength size | 5.5-14um |
Corresponding time | <1second |
Precautions:
1. The temperature measuring equipment should be used in a room with a room temperature of 10 degrees Celsius to 40 degrees Celsius. Do not install the temperature measuring equipment to the vent, and ensure that there is no heating source within 3 meters;
2. People entering the room from a cold outdoor environment will affect the temperature measurement accuracy, and the forehead temperature testneeds to be performed indoors for three minutes without covering the forehead and the temperature is stable;
3. The temperature read by the temperature measuring device is the temperature in the forehead area. When there is water, sweat, oil or thick makeup on the forehead or the elderly have more wrinkles, the read temperature will be lower than the actual temperature, and ensure there is no hair or clothing in the area.
Download PDF